Troubleshooting
IMER Step-Up 120 problems and fixes
The troubleshooting table of the IMER manual 3226875 R16, problem by problem: the likely causes, what the manual says to do and the parts for each fix.
- problems
- 21
Machine does not start, compressor does not start, On the display is visualized ---------------------(MONOPHASE)
Possible cause What to do The supply voltage is too high To check that the supply voltage does not exceed 260V Qualified person: this fix involves electrical, pressure or engine work.
Source: IMER manual 3226875 R16, page 38
The machine stops during operation. ERR00 : Hopper grille open or incorrectly located.(MONOPHASE)
Possible cause What to do Hopper grille open or incorrectly located. Ensure the grille is properly located Connection plug not inserted Insert connection plug System malfunction. Contact Assistance Service Qualified person: this fix involves electrical, pressure or engine work.
Source: IMER manual 3226875 R16, page 39
The machine stops during operation. ERR01 : High circuit board temperature (Inverter).(MONOPHASE)
Possible cause What to do High circuit board temperature (Inverter). Wait for it cool down Source: IMER manual 3226875 R16, page 39
The machine stops during operation. ERR02 : High screw pump motor temperature.(MONOPHASE)
Possible cause What to do High screw pump motor temperature. The motor has been subjected to overloading for a long time. Wait for it cool down Source: IMER manual 3226875 R16, page 39
The machine stops during operation. ERR03 : Too much power required from screw pump motor (motor jammed).(MONOPHASE)
Possible cause What to do Too much power required from screw pump motor (motor jammed). Check the mixture Resize the length of the piping Source: IMER manual 3226875 R16, page 39
The machine stops during operation. ERR04 : Screw pump motor overload warning.(MONOPHASE)
Possible cause What to do Screw pump motor overload warning. Check the mixture Decrease the speed of the screw pump motor Ensure that the power voltage is > 205V Source: IMER manual 3226875 R16, page 39
The machine stops during operation. ERR05 : The compressor turns on and off too frequently (<5 start/min)(MONOPHASE)
Possible cause What to do The compressor turns on and off too frequently (<5 start/min) High leakage from the piping Replace the gaskets Qualified person: this fix involves electrical, pressure or engine work.
Source: IMER manual 3226875 R16, page 39
The machine stops during operation. ERR06 : Compressor blocked at the start(MONOPHASE)
Possible cause What to do Compressor blocked at the start Switch off and switch on the compressor Source: IMER manual 3226875 R16, page 39
The machine stops during operation. ERR07 : Current loss to ground or system malfunction.(MONOPHASE)
Possible cause What to do Current loss to ground or system malfunction. Contact Assistance Service. Check for water in system. Qualified person: this fix involves electrical, pressure or engine work.
Source: IMER manual 3226875 R16, page 39
The machine stops during operation. ERR 08 : Power voltage too low:(MONOPHASE)
Possible cause What to do Power voltage too low: Lower than 180V for versions 220V Lower than 85V for versions 115V Check power supply connection Qualified person: this fix involves electrical, pressure or engine work.
Source: IMER manual 3226875 R16, page 39
The machine stops during operation. ERR09 : Overload current on motor vibrating screen(MONOPHASE)
Possible cause What to do Overload current on motor vibrating screen Check the motor vibrating screen Disconnect any electrical device on the power grid Qualified person: this fix involves electrical, pressure or engine work.
Source: IMER manual 3226875 R16, page 39
The machine stops during operation. ------------ : Voltage input >265V(MONOPHASE)
Possible cause What to do Voltage input >265V Check power supply connection Qualified person: this fix involves electrical, pressure or engine work.
Source: IMER manual 3226875 R16, page 39
The machine stops during operation. BLOC : Motor screw pump jammed(MONOPHASE)
Possible cause What to do Motor screw pump jammed Check whether the stator and rotor are jammed together Parts named in these fixes, from the Step-Up 120 parts book
- 2L6 Pump Stator, Yellow, for IMER Step-Up 1201107077 · drawing 16, ref 7$319.00
- 2L6 Pump Rotor for IMER Step-Up 1201107078 · drawing 16, ref 6$549.00
Check the part number on your machine or in its parts book before you order.
Source: IMER manual 3226875 R16, page 39
The machine stops during operation. STOP : Inlet air on compressor is closed(MONOPHASE)
Possible cause What to do Inlet air on compressor is closed Jet nozzle closed Nozzle clogging Pipe clogging from machine The warning automatically disappears if the machine starts normally after the halt. Clean the air nozzle and unblock the air hose. Qualified person: this fix involves electrical, pressure or engine work.
Source: IMER manual 3226875 R16, page 39
Machine does not start, compressor does not start and the blue light is OFF(THREEPHASE)
Possible cause What to do Electric current No current delivered to connector of site panel (fuses)? No power delivered to machine (defective connector connection? loose cable?) Main switch not turned on It miss a phase Check point listed alongside Qualified person: this fix involves electrical, pressure or engine work.
Source: IMER manual 3226875 R16, page 40
The machine stops during operation. The following texts appear on display: Material pressure of friction on screw too high(THREEPHASE)
Possible cause What to do Material pressure of friction on screw too high Reduce flow rate before restarting Low level of binder in mix, add cement or lime Sand not perfectly suitable for pumping;correct Pipeline length excessive;reduce Source: IMER manual 3226875 R16, page 40
The machine stops during operation. The following texts appear on display: Inverter temperature too high(THREEPHASE)
Possible cause What to do Inverter temperature too high Wait for the motor to cool sufficiently before restarting Check the power line Qualified person: this fix involves electrical, pressure or engine work.
Source: IMER manual 3226875 R16, page 40
The machine stops during operation. The following texts appear on display: Motor temperature too high(THREEPHASE)
Possible cause What to do Motor temperature too high Wait for the motor to cool sufficiently before restarting Source: IMER manual 3226875 R16, page 40
The machine stops during operation. The following texts appear on display: Inverter module current too high(THREEPHASE)
Possible cause What to do Inverter module current too high Probable external short circuit Qualified person: this fix involves electrical, pressure or engine work.
Source: IMER manual 3226875 R16, page 40
The machine stops during operation. The following texts appear on display: System overload(THREEPHASE)
Possible cause What to do System overload Pump seized Source: IMER manual 3226875 R16, page 40
The machine stops during operation. The following texts appear on display: Supply voltage too low(THREEPHASE)
Possible cause What to do Supply voltage too low Check that the power voltage is between 210 and 230V with the machine running and that the cables are correctly sized, and that there is no other equipment (cranes, hoists, saws, cement mixers etc..) connected to the same power line Qualified person: this fix involves electrical, pressure or engine work.
Source: IMER manual 3226875 R16, page 40