Troubleshooting
IMER Mortarman 120 Plus problems and fixes
The troubleshooting table of the IMER manual 3230425 R07, problem by problem: the likely causes, what the manual says to do and the parts for each fix.
- problems
- 3
Motor does not start when switch is turned
Possible cause What to do Defective power cable Check power cables * Plug not inserted in socket correctly Ensure correct connection Power cable from plug to control panel detached Remake the connection * Loose wire inside motor circuit board Remake the connection * Loose wire inside motor circuit board Remake the connection * Limit switch malfunction Replace limit switch * Faulty main switch Replace switch * The overload safety device has been activated Wait for a few minutes and then try restarting the machine Tank guard open Close tank guard Qualified person: this fix involves electrical, pressure or engine work.
Parts named in these fixes, from the Mortarman 120 Plus parts book
- Limit Switch for IMER Step-Up 120 and Mortarman 120 Plus3214791 · drawing 2, ref 16$89.00
Check the part number on your machine or in its parts book before you order.
Source: IMER manual 3230425 R07, page 6
Outlet does not open
Possible cause What to do Blocked outlet guard Remove and clean outlet guard Source: IMER manual 3230425 R07, page 6
During mixing, the blades slow down or jam
Possible cause What to do Belts are worn or slack Tension or replace the belts Source: IMER manual 3230425 R07, page 6