IMER Mix 60 Plus problems and fixes

The troubleshooting table of the IMER manual, problem by problem: the likely causes, what the manual says to do and the parts for each fix.

problems
3
Disconnect the machine from power before any check. Fixes marked Qualified person involve electrical, pressure or engine work: have them done by a qualified technician and follow the safety instructions in your IMER manual.
  1. The motor does not start when switched on
    Possible causeWhat to do
    No power on power cableCheck power cables
    Plug not inserted correctly in socketEnsure correct connection
    Faulty power cable to electrical panelChange power cable
    Loose wire in electrical panelReconnect wire
    Loose wire in motor terminal boardReconnect wire
    Faulty main switchReplace switch
    Residual current circuit breaker trippedReset switch. If it does not reset, refer to a qualified electrician to check the electrical system to ensure complete safety.

    Qualified person: this fix involves electrical, pressure or engine work.

    Source: IMER manual, page 6

  2. The motor does not stop when the safety grid is lifted
    Possible causeWhat to do
    Faulty limit switchReplace limit switch

    Qualified person: this fix involves electrical, pressure or engine work.

    Parts named in these fixes, from the Mix 60 Plus parts book

    Check the part number on your machine or in its parts book before you order.

    Source: IMER manual, page 6

  3. Motor starts with difficulty
    Possible causeWhat to do
    Mixture is too stiffReduce mixture quantity or dilute and try again.

    Source: IMER manual, page 6