Troubleshooting
IMER Combicut 250 VA problems and fixes
The troubleshooting table of the IMER manual, problem by problem: the likely causes, what the manual says to do and the parts for each fix.
- problems
- 3
The motor does not start when the start switch is pressed
Possible cause What to do Current does not reach the supply line Check the line * The socket and plug are not connected properly Restore correct connection The differential switch is off Turn the differential switch on The power cable from the plug to the panel is cut off Change the cable * An electric wire inside the motor terminal strip is cut off Restore the connection * An electric wire inside the panel is cut off Change the switch * The start switch is faulty Change the switch * Qualified person: this fix involves electrical, pressure or engine work.
Source: IMER manual, page 5
Cooling water fails to reach the blade
Possible cause What to do Low water level in tank Restore the water level Pump filter clogged Clean the pump filter Current fails to reach the pump Check the pump electrical supply * Pump failure Change the pump * Qualified person: this fix involves electrical, pressure or engine work.
Source: IMER manual, page 5
The blade does not cut
Possible cause What to do Blade fitted in the opposite direction to that of rotation Remove the blade and reposition it in the direction shown on the blade label Worn blade Change the blade Source: IMER manual, page 5